Brand Name : Delta
Model Number : KFZ
Certification : ISO9001
Place of Origin : China
MOQ : 1 set Transformer Test Equipment
Price : USD1.0 / set Transformer Test Equipment
Payment Terms : T/T, Western Union
Supply Ability : 1000 sets Transformer Test Equipment per month
Delivery Time : 10 days
Packaging Details : Kfz Transformer Test Equipment is packed in veneer case
Functions : Automatic Capacity Transformer Power Analyzer
Application : Test Transformer Capacity, Load Loss, etc
Current output : 0-10A
Voltage measurement : 0-10V
Frequency : 45-65Hz
Dimension : 400×300×170mm
Net weight : 6kg
Power supply : AC220V ± 10%, 50Hz/60Hz
Warranty : One year
Service : OEM service is available
Total Weight : 13KG
Working Power Supply : AC220V,50Hz
Input Power : AC220V±10%
Language : English
KFZ Transformer Load Loss and No Load Loss Testing Transformer Test Equipment can measure transformer capacity, type, no-load current, no-load loss, short circuit (load) loss, resistance voltage, etc.
KFZ Transformer Load Loss and No Load Loss Testing Transformer Test Equipment is small in volume, light in weight, in high accuracy, with steady property, easy to operation can replace the traditional testers.
KFZ Transformer Load Loss and No Load Loss Testing Transformer Test Equipment is displayed by LCD, operated by menu, with friendly interface, is the first choice for all customers.
KFZ Transformer Load Loss and No Load Loss Testing Transformer Test Equipment can accurately measure the capacity of the distribution transformer, convenient and accurate;
Automatically check if the wire was correctly connected, and display vector diagram of three-phase current, and voltage when testing three-phase transformer;
KFZ Transformer Load Loss and No Load Loss Testing Transformer Test Equipment can do a loading test for a substation transformer under 1000KVA; can do a loading test with 1/3 of the rated current for a substation transformer under 3150KVA (the device can convert to the loading losses parameters if the rated current under 1/3 of the rated current);
Polarity testing: single-phase power transformer, three-phase power transformer, CT, PT;
Vector group testing: three-phase power transformer;
All the related test results are automatically corrected, such as the waveform correction, temperature correction, non-rated voltage correction, calibration, and other non-rated current correction, so test result is more accurate.
Can preset 40 group parameters of testes objects, and these parameters can be deleted or added at any time as needed, so it is easy for use.
With an electronic clock, auto records the data, and time, it is good for saving and managing the test results. With built-in printer;
Data (specimen setting, test results, measurement time) can be saved on power failure and can be reviewed, it can store 500 groups of test results, and can connect with computers to transmit data.
Allowance external connecting CT and PT to make extension measurement can test the specimen with any parameters.
Item Name | KFZ Transformer Load Loss and No Load Loss Testing Transformer Test Equipment |
Current output | 0 ~ 10A |
Voltage measurement | 0 ~ 10V |
Test Capacity | 10KV oil-immersed, dry-type transformers: 30KVA ~ 2500KVA |
35KV oil-immersed transformers: 50KVA ~ 31500KVA | |
20KV dry type transformers: 50KVA ~ 2500KVA | |
35KV dry type transformers: 50KVA ~ 2000KVA | |
Voltage | 0~450V (phase voltage), 0 ~ 800V (line voltage), auto-switch the measurement range |
Current | 0 ~ 100A, auto-switch the measurement range |
Frequency | 45Hz ~ 65Hz |
Voltage Accuracy | 20 ~ 100V, ± 0.2% FS; 100 ~ 450V, ± 0.2% |
Current Accuracy | 0.5 ~ 10A, ± 0.2% FS; 10 ~ 100A, ± 0.2% |
Power Accuracy | ± 0.5% (CosΦ> 0.1), ± 1.0% (0.02 <CosΦ <0.1) |
Dielectric strength | The insulation resistance between voltage, the current input terminal and the chassis≥100MΩ. |
Between power supply input terminal and the shell can withstand 2KV (rms), for 1 minute | |
Dimension | 400×300×170mm |
Weight | 6kg (not including test lines) |
Working Temperature | -5°C~40°C |
Working Humidity | <95%(25°C) |
Altitude | <2500m |
Power supply | 220VAC±10%,45Hz~55Hz. |
![]() |
KFZ Transformer Load Loss and No Load Loss Testing Transformer Test Equipment Images |